Isolation Probe system SE-6000 / SE-6011

For High voltage, High magnetic field strength environment, floating measurement and long distance test points

Features and application range

Isolation Probe system SE-6000 / SE-6011TOP

 

Contributes to the safety for the high voltage environment tests

Increases measurement quality with differential probes

Measures noise resistance very effectively

Supports wide range of objects such as lightning surge and charging tests and etc.

Measures Distant points (Switches, Transportation equipment and etc.)

Analyzes failure factors when multiple abnormal operations happened at the distant places.
(The Isolation Unit can be set at each place, up to 4 sets in total. )

 

 

Isolated by optical digital transmission method

Transmitter Isolation Unit SE-6011

Receiver Isolation Amp SE-6000

Operation Temperature : -15 to 50

 

Input/Output : 4CH

Operation Humidity : 5%-80%RH
(no condensation)

 

LAN(control), USB memory

Continuous operation hours : 30hours
(twin batteries at full charge)

 

Operation temperature : 0 to 40

Dimensions : 89Wx203Hx298D(mm)

 

Dimensions : 226Wx100Hx366D(mm)

Weight : Approx. 2.4kg(Excluding battery packs)

 

 

Weight : Approx. 2.5kg(Including handle and protector)

Specifications


ISOLATION UNIT SE-6011 (sending side)

Item

Specification

Number of channels

1

Frequency BandWidth

DC - 30MHz (-3dB)

Input impedance

1M Ω //20pF

Input coupling

DC, AC, GND

Input range (Full scale)

at output range ± 1V (50-ohm), ± 2V (1M-ohm) ± 50mV, ± 100mV, ± 200mV, ± 500mV, ± 1V, ± 2V, ± 5V, ± 10V, ± 20V, ± 50V at output range ± 0.8V (50-ohm), ± 1.6V (1M-ohm) ± 40mV, ± 80mV, ± 200mV, ± 400mV, ± 800mV, ± 2V, ± 4V, ± 8V, ± 20V, ± 40V

CMRR

100dB(80Hz)

Functions

Offset variable, Probe sense, Auto range, Self Cal. (Controlled from the SE-6000 [Receiving side])

Operation time

Battery 1pce: 12 hours Battery 2pces: 24 hours *1 pce equipped as standard


ISOLATION AMP SE-6000 (Receiving side)

Item

Specification

Number of channels

4

DAC

14bit 100MS/s

Output voltage (Impedance)

± 1V (50-ohm load), ± 2V (1M-ohm load) In DSO mode: ± 800mV (50-ohm load), ± 1.6V (1M-ohm load)

Monitor display

4.3" Color LCD back light : Select High / Low for display and selection of setting conditions of the SE-6010 (ISOLATION UNIT)

Auto range

Range, Offset auto detection

Input (Optical I/F Connector)

Twin LC connector x 4

Output

BNC × 4

Power Source

AC100 to 240V (50/60Hz)

Ordering Information

Model

Description

SE-6000

Receiver Isolation Amp

SE-6011

Transmitter Isolation Unit

CH-5050A

Battery charger (2-bay type)

NH-2054

Battery(1pc. for SE-6011 as a standard, twin-pack available for each SE-6011

SE-605

3m

Optical fiber cable (also for field use)

SE-606

10m

SE-607

50m

Made to order

200m