Isolation Probe system
SE-6000 / SE-6011
|
For High voltage, High magnetic field
strength environment, floating measurement and long
distance test points |
Features and application range
![]()
|
|
![]()
|
|
Contributes
to the safety for the high voltage environment tests |
|
|
|
|
|
Increases
measurement quality with differential probes |
|
|
|
|
|
Measures
noise resistance very effectively |
|
|
|
|
|
Supports wide
range of objects such as lightning surge and charging tests and etc. |
|
|
|
|
|
Measures
Distant points (Switches, Transportation equipment and etc.) |
|
|
|
|
|
Analyzes
failure factors when multiple abnormal operations happened at the distant
places. |
|
|
|
|
|
|
|
|
||||
|
Transmitter Isolation
Unit SE-6011 |
Receiver Isolation Amp
SE-6000 |
|||
|
|
Operation Temperature : -15℃ to 50℃ |
|
|
Input/Output : 4CH |
|
|
Operation Humidity : 5%-80%RH |
|
|
LAN(control), USB
memory |
|
|
Continuous
operation hours : 30hours |
|
|
Operation temperature : 0℃ to 40℃ |
|
|
Dimensions : 89Wx203Hx298D(mm) |
|
|
Dimensions :
226Wx100Hx366D(mm) |
|
|
Weight : Approx.
2.4kg(Excluding battery packs) |
|
|
Weight : Approx.
2.5kg(Including handle and protector) |
![]()
Specifications
![]()
ISOLATION UNIT SE-6011 (sending side)
|
Item |
Specification |
|
Number of channels |
1 |
|
Frequency BandWidth |
DC - 30MHz (-3dB) |
|
Input impedance |
1M Ω //20pF |
|
Input coupling |
DC, AC, GND |
|
Input range (Full scale) |
at output range ± 1V (50-ohm), ± 2V
(1M-ohm) ± 50mV, ± 100mV, ± 200mV, ± 500mV, ± 1V, ± 2V, ± 5V, ± 10V, ± 20V, ±
50V at output range ± 0.8V (50-ohm), ± 1.6V (1M-ohm) ± 40mV, ± 80mV, ± 200mV,
± 400mV, ± 800mV, ± 2V, ± 4V, ± 8V, ± 20V, ± 40V |
|
CMRR |
100dB(80Hz) |
|
Functions |
Offset variable, Probe sense, Auto range,
Self Cal. (Controlled from the SE-6000 [Receiving side]) |
|
Operation time |
Battery 1pce: 12 hours Battery 2pces: 24
hours *1 pce equipped as standard |
![]()
ISOLATION AMP SE-6000 (Receiving side)
|
Item |
Specification |
|
Number of channels |
4 |
|
DAC |
14bit 100MS/s |
|
Output voltage (Impedance) |
± 1V (50-ohm load), ± 2V (1M-ohm load) In
DSO mode: ± 800mV (50-ohm load), ± 1.6V (1M-ohm load) |
|
Monitor display |
4.3" Color LCD back light : Select High / Low for display and selection of
setting conditions of the SE-6010 (ISOLATION UNIT) |
|
Auto range |
Range, Offset auto detection |
|
Input (Optical I/F Connector) |
Twin LC connector x 4 |
|
Output |
BNC × 4 |
|
Power Source |
AC100 to 240V (50/60Hz) |
![]()
Ordering Information
![]()
|
Model |
Description |
|
|
SE-6000 |
Receiver Isolation Amp |
|
|
SE-6011 |
Transmitter Isolation Unit |
|
|
CH-5050A |
Battery charger (2-bay type) |
|
|
NH-2054 |
Battery(1pc. for SE-6011 as a standard, twin-pack
available for each SE-6011 |
|
|
SE-605 |
3m |
Optical fiber cable (also for field use) |
|
SE-606 |
10m |
|
|
SE-607 |
50m |
|
|
Made to order |